Floor-wall constructions

Informations for professional construction of building joints along rising building components (such as columns).

Floor-wall construction W1

Profile design floor-wall connection W1
for expansion joints on rising building components with mounting bracket upwards. Raise of the waterproofing membrane to 150 mm above the upper edge of the profile (flashing on request).

System example: VA.8.95/52 F W1

Fitting floor-wall connection W1
if the expansion joint passes directly on rising building components, two corner pieces are required horizontally at the transition from floor-floor to floor-wall (Z-shaped design). 

System example: VA.8.95/52 F W1

Profile design floor-wall connection W1
for expansion joints offset to rising building components with mounting bracket upwards. Raise of the waterproofing membrane to 150 mm above the upper edge of the profile (flashing on request).

System example: VA.8.95/52 F W1

Fitting floor-wall connection W1
if the expansion joint passes offset to rising building components, a fitting profile is required at the transition from floor-floor to floor-wall. A straight (aligned) profile run is therefore given.

System example: VA.8.95/52 F W1

Floor-wall constructions W2

Profile design floor-wall connection W2
for expansion joints on rising building components with mounting bracket downwards. Installation only possible from profile height of approx. 60 mm.

System example: VA.8.95/60 W2

Fitting floor-wall connection W2
if the expansion joint passes directly on rising building components, two corner pieces are required horizontally at the transition from floor-floor to floor-wall (Z-shaped design).

System example: VA.8.95/60 W2

Floor-wall constructions W3

Profile design floor-wall connection W3
for expansion joints on rising building components with mounting bracket upwards. Raise of the waterproofing membrane to 50 mm above the upper edge of the profile.

System example: VA.8.95/20 W3

Fitting floor-wall connection W3
if the expansion joint passes directly on rising building components, a fitting profile is required at the transition from floor-floor to floor-wall. A straight (aligned) profile run is therefore given.

System example: VA.8.95/20 W3

Floor-wall constructions W4

Profile design floor-wall connection W4
for expansion joints on rising building components with mounting bracket upwards. Raise of the waterproofing membrane to 150 mm above the upper edge of the profile.

System example: VA.8.95/52 F W4

Fitting floor-wall connection W4
if the expansion joint passes directly on rising building components, a fitting profile is required at the transition from floor-floor to floor-wall. A straight (aligned) profile run is therefore given.

System example: VA.8.95/52 F W4

Floor-wall constructions W5

Profile design floor-wall connection W5
for expansion joints on rising building components with mounting bracket upwards. Raise of the waterproofing membrane to 150 mm above the upper edge of the profile (flashing on request).

System example: VA.8.95/52 F W5

Fitting floor-wall connection W5
if the expansion joint passes directly on rising building components, a fitting profile is required at the transition from floor-floor to floor-wall. A straight (aligned) profile run is therefore given.

System example: VA.8.95/52 F W5